
BoxSAFE CX
- Non Fire-Rated
- 8 ft x 40 ft x 8' 5"
- 50 Qty 55 Gallon Drums
- 9 Pallets or Totes
- 302 Square Feet storage
Compliant storage and rental solutions for Phosphorus Pentachloride (Cl₅P). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Phosphorus Pentachloride is a CORROSIVE CHEMICAL and contact can severely irritate and burn the skin and eyes with possible eye damage. * Breathing Phosphorus Pentachloride can irritate the nose and throat. * Breathing Phosphorus Pentachloride can irritate the lungs causing coughing and/or shortness of breath.
Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 2), H330 Skin corrosion (Category 1B), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - repeated exposure, Inhalation (Category 2), H373
Dry Chemical fire suppression is recommended for Phosphorus Pentachloride
Guidance: Dry Chemical fire suppression is generally recommended for Phosphorus Pentachloride (Cl₅P). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Dry powder.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Phosphorus Pentachloride should account for its listed hazards, climate control needs (<30 C), and segregation requirements. Phosphorus Pentachloride is not compatible with ALCOHOLS; AMINES; ALUMINUM; SODIUM; POTASSIUM; STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); MAGNESIUM OXIDE; and a heated solution of PHOSPHORUS PENTACHLORIDE in NITROBENZENE
Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.
Properties: a) Appearance Form: powder Colour: light yellow b) Odour pungent c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: 179 - 181 °C (354 - 358 °F) f) Initial boiling point and boiling range 160 °C (320 °F) at 1,013 hPa (760 mmHg) g) Flash point Not applicable h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits No data available k) Vapour pressure < 1 hPa (< 1 mmHg) at 20 °C (68 °F)
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Phosphorus Pentachloride in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: <30 C. Compatibility notes: Phosphorus Pentachloride is not compatible with ALCOHOLS; AMINES; ALUMINUM; SODIUM; POTASSIUM; STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); MAGNESIUM OXIDE; and a heated solution of PHOSPHORUS PENTACHLORIDE in NITROBENZENE US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Phosphorus Pentachloride is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.
Phosphorus Pentachloride is listed as: Consult the SDS and applicable hazard classification. Acute toxicity, Oral (Category 4), H302 Acute toxicity, Inhalation (Category 2), H330 Skin corrosion (Category 1B), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - repeated exposure, Inhalation (Category 2), H373
Dry Chemical fire suppression is generally recommended for Phosphorus Pentachloride (Cl₅P). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Phosphorus Pentachloride. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.